Bomir online Worldwide Distribution Network For SMT, LVA, and ESD Equipment View Shopping Cart USA
Phone: 570 842-4725
Fax: 570 842-4290
Cart: (Empty)

Quick Search

Goot Logo

GOOT Sale

sale_bomir.jpg

AW75-BK.jpg

Antistatic Wheels

Toroidal Transformers Built In Europe

QUALITY, GOOD DELIVERIES, VERY COMPETITIVE PRICING

All transformers are built and tested in accordance with the following standards:

IEC 742, EN60742, VDE 551, PN-88/E 08105

Guaranteed features:

  • Double insulation on primary leads
  • Insulation class B (130 deg C)
  • Insulation break down voltage min 5000V AC (less than .750 mA at 3750 V)
  • Built in primary winding thermal cut off at 115 deg C (upon request)
  • Power ranges: From 10 VA to 2500 VA
  • Input voltages as required (See transformer information/design sheet)
  • Up to 10 secondary voltages
  • Frequencies 50 to 400 Hz (Higher for audio transformers)
  • Private labels if required

We can also build all other devices on toroidal cores. Inquires are welcomed.


To assure expedient quotation please complete "Transformer information sheet" to allow us to quote without further questions.

RFQ and
TOROIDAL TRANSFORMER INFORMATION SHEET:
 
Name, P/N, ID# ................................
Quantity required ................................
When needed ................................
 
   

Full load

No load Lead lengths Lead Color

Prim volt (V)

Psec (VA) Usec (V) Uo sec (V) LP mm Primary
  Isec (A) Tol +(V) Tol +(V) (+/- 5 mm) Secondary lead 1

Frequency (Hz)

R1 (ohm) Tol -(V) Tol -(V) LS mm Secondary lead 2
           
           
           
           
           
           
           
           
           
           
           
           

LP=leads primary
LS=leads secondary

ADDITIONAL INFORMATION:

Thermal protection required at cut temperature:...........................Thermal cut off at 115°C is recommended.

TRANSFORMER DESIGN TABLE:

PARAMETER

FILL IN DIMENSIONS

UNITS

VERSION A

LP   mm +/-5
LPS   mm +/-5
LS   mm +/-5
OD   mm
ID   mm
H   mm

VERSION B

d   mm
CIRCLE ONE CHOICE
VERSION A B
115 °C
Thermal Protection
YES NO

LP=Lengths of primary leads
LPS=Lengths of double insulation on primary leads
LS=Lengths of secondary leads
H=Height
OD=Outside diameter
ID=Inside diameter
d=Diameter of mounting hole (in Version B only)

GENERAL INFORMATION:

  1. TRANSFORMER ARE BUILT AND TESTED IN ACCORDANCE WITH THE FOLLOWING STANDARDS: IEC742, EN60742, VDE 551, PN-88E 08105
  2. Thermal protection is optional
  3. Version B is recommended for better cooling and mounting
  4. Transformers are supplied with 2 rubber gaskets.

Please return this RFQ sheet by E-mail sales@bomir.com or fax 570.842.4290 to Bomir, Inc.